Cette page existe aussi en français. Lire en français
Sensor reference
Every Adekio sensor type: what it measures, what it needs, and what to know.
A sensor is added from an item’s page (Monitoring > Add a sensor); its behaviour comes from its profile (Settings > Monitoring > Profiles). Thresholds and settings can be overridden sensor by sensor: see Profiles, thresholds and rules. Built-in profiles keep their French names in the interface.
Availability and network
Ping
Checks that the device answers and measures the response time (icmp.rtt_ms), packet loss and jitter. It only needs
the item’s address, with ICMP allowed by the firewalls. Built-in profile: Disponibilité (ICMP).
For telephony, add to the profile the jitter (icmp.jitter_ms, warning at 30 ms) and the estimated voice
quality (icmp.mos, from 1 to 4.5; warning below 3.6, critical below 3.1). Polled by a site’s collector towards the
IP PBX or the carrier, it shows the quality of that site’s link.
TCP port
Checks that a port accepts connections and measures the connection time. The port goes in the address (host:443).
Text sent then Text expected in response check a service that answers with a banner (SMTP 220, FTP…). Built-in
profile: Port TCP.
Telephony (SIP)
Sends a SIP OPTIONS request over UDP (port 5060 by default) to the IP PBX, SBC or carrier trunk. Any answer, even a refusal (401, 403, 404), shows the server is alive; a critical threshold at 500 on the response code reports 5xx and 6xx errors, including 503 (trunk unavailable).
Web and certificates
Web page (HTTP)
Queries a web address: availability, response code, response time and, when the profile asks, the presence of a text. Settings: expected codes, expected text, certificate check. Built-in profile: Site web (HTTP/HTTPS).
TLS certificate
Reads the certificate of a secure service (host:443): days left before expiry (floor threshold) and validity of the
chain. Built-in profile: Certificat TLS.
REST / JSON API
Calls an API (GET, POST, PUT, PATCH, headers, body, expected codes) and extracts values from the answer. One measure per
value: rest.queue with its JSON path (data.queues[0].size; items.# gives the length of a list), its thresholds
or states per value. Optional credential: "User and password" or "Token (Bearer)".
SNMP devices
SNMP
Reads the device’s counters depending on the profile: CPU, memory, disks, uptime, and every interface (status, traffic, errors, usage per port). Needs an SNMP v2c or v3 credential and the SNMP agent running (UDP 161). Built-in profile: SNMP — système. MIBs, SNMP tables and states per value: see Advanced SNMP.
UPSs
Profile Onduleur (UPS-MIB) (RFC 1628 standard: Eaton, Riello, Socomec, APC with the standard MIB…) or Onduleur APC (PowerNet) (APC network cards): battery status, on battery, charge, remaining runtime, output load, input voltage; "Battery replacement" for APC.
Windows and Linux servers
Windows (agentless)
Queries Windows over WinRM: CPU, memory, volumes, services, processes, event log, WQL queries. Needs a WinRM credential
and WinRM enabled (winrm quickconfig). Built-in profiles: Windows (WinRM), Windows IIS, Windows Active
Directory, Windows Exchange, Windows Hyper-V. See Windows and Linux servers.
Linux (agentless)
Connects over SSH and reads CPU, memory, swap, load, volumes, systemd services, processes, journal and commands. Needs an SSH credential (password or key). Built-in profile: Linux (SSH).
Telegraf agent
Receives the measurements sent by Telegraf installed on the machine, with an agent token. Built-in profile: Agent (Telegraf). See Agents.
Applications and services
Database
Runs a single read query (PostgreSQL, SQL Server, MySQL / MariaDB) and reads its value and duration: for example
SELECT count(*) AS pending FROM orders WHERE status = 'blocked', with a measure sql.pending on the pending column of
the first row. Writes, locks and stored procedures (EXEC) are refused.
Read-only account
The query runs in a read-only transaction on PostgreSQL and MySQL. Always give the sensor an account that can only read; it is essential on SQL Server.
DNS
Resolves a name on a DNS server (the item’s address) and measures the response time: name, type (A, AAAA, MX, PTR…), optional expected value.
Time server (NTP)
Offset of the server’s clock against Adekio’s (warning at 500 ms, critical at 2 s by default) and stratum.
Directory (LDAP)
Anonymous bind or bind with a "User and password" credential (DN or account@domain), over LDAP or LDAPS, then a search when a base is given (number of entries found, bind and search times).
Veeam backups
For Veeam Backup & Replication v11 or later, through the REST API (port 9419) with an account holding the Veeam Backup Viewer role. Each active job has its series (0 success, 1 warning, 2 failed): the alert names the failed job.
Hardware and virtualisation
Physical server (Redfish)
Reads the hardware status through the server’s controller (iLO, iDRAC, XClarity…): overall health (the alert names the failing power supply, fan or probe), power state, hottest sensor, power used. The sensor’s address is that of the controller, with a read-only account. Built-in profile: Serveur physique (Redfish).
VMware vSphere
A sensor on the vCenter item (or a standalone ESXi), with a read-only vCenter account: each powered-on host and each accessible datastore has its series (host CPU and memory, datastore space used), with its thresholds.
Hyper-V
Profile Windows Hyper-V (WinRM): management service, hypervisor load, virtual machines in critical health.
Scripts and computations
Script
Runs a script (PRTG, Nagios or Adekio JSON format) and reads the values it returns. See Script sensors.
Computed sensor
Computes a value from the measurements of other items (sum, average, count, formula), without polling anything. See Computed sensors and business services.
Was this page helpful?
Thank you for your feedback. Tell us what is missing